Description
For Downloads | Data Sheet – User Manual – Other Documents – Certificates
Setup Software / Testing Software |
For Purchase | Call / WhatsApp / Telegram : +91 8148834200 email: sales@embsys.in |
For Support | Call / WhatsApp / Telegram : +91 8148834211 |
Before Purchase | Choose the output model you need RS485 Output | 4-20mA Output | 0-5v Output | 0-10v Output |
Product Description
The duct ozone sensor is professionally used in the measurement of ozone concentration in pipelines. It adopts a waterproof shell design, pipeline installation, convenient on-site installation, and uses anti-interference circuit design. Can withstand various strong electromagnetic interferences such as on-site frequency converters. The duct ozone sensor is powered by 10-30V wide voltage, and the protection level of the shell is high, which can adapt to various harsh conditions on-site.
Detailed Images
FEATURES:
1. Using high-sensitivity gas detection probes imported from the United States, and using a high-performance signal acquisition circuit, can accurately measure the ppm level O3 concentration, the signal is stable, and the accuracy is high.
1. Using high-sensitivity gas detection probes imported from the United States, and using a high-performance signal acquisition circuit, can accurately measure the ppm level O3 concentration, the signal is stable, and the accuracy is high.
2. The product adopts a pipe-type waterproof shell, which is easy to install and has a high protection level.
Technical Parameter
Power supply
|
10~30V DC
|
|||
Average power consumption
|
0.1W
|
|||
output signal
|
RS485/0-5V/0-10V/4-20ma
|
|||
Ozone measurement range
|
0~10.00ppm, 0~100ppm
|
|||
Operating temperature
|
-10℃~55℃, 15%RH-90%RH (no condensation)
|
|||
Working humidity
|
15%RH-90%RH (no condensation)
|
|||
Working pressure
|
91~111Kpa
|
|||
Data update time
|
1s
|
|||
Repeatability
|
≤2%
|
|||
Stability
|
≤7% signal value/year
|
|||
Response time
|
≤35S
|
|||
Resolution |
Range 0~10ppm: 0.01ppm
|
|||
Range 0~100ppm: 1ppm
|
||||
Accuracy
|
0~10ppm:±6%FS(@5ppm,25℃,50%RH) 0~100ppm:±6%FS(@50ppm,25℃,50%RH)
|
|||
Zero drift |
Range 0~10ppm: ≤±1ppm
|
|||
Range 0~100ppm: ≤±5ppm
|