Description
Gas Analyzer Features: 1. Adopt first-line electrochemical sensors of major brands, stable and durable. 2. Using remote infrared remote control technology, parameters can be modified without disassembly. 3. Support a variety of gas detection, and the range can be customized. 4.485 communication interface standard ModBus-RTU communication protocol, address and baud rate can be set, and the communication distance is up to 2000 meters. 5. High-quality LCD screen, the value can be directly viewed on site. 6. The on-site power supply adopts 10~30V DC wide-voltage power supply, which can adapt to a variety of on-site DC power supplies. 7. The gas leak detector adopts wall-mounted shell, easy to install.
Power supply
|
10~30V DC
|
|
Average power consumption
|
0.6W(24VDC)
|
|
Output signal
|
485 output (standard Modbus protocol)
|
|
Repeatability
|
NH3/H2/CO(1000ppm)/H2S/CH4/NO2/SO2/O3/PH3:≤2%
CO(2000ppm) :≤3% O2:≤1% |
|
Stability
|
CO(1000ppm)/H2S/H2/NO2/SO2/NH3/PH3
|
≤2% signal value/month
|
CH4/O3
|
≤7% signal value/year
|
|
CO(2000ppm)/O2
|
≤5% signal value/year
|
|
Operating temperature
|
H2/CO/H2S/CH4/NO2/SO2/O2/NH3/PH3/O3:-10~50℃
|
|
Working humidity
|
NH3/H2/CO/H2S/NO2/SO2/O3/PH3:15~90%RH No condensation
O2:5~95%RH No condensation CH4:0~95%RH No condensation |
|
Work pressure
|
NH3/H2/CO(1000ppm)/H2S/SO2/O2/O3/PH3
|
90~110Kpa
|
NO2
|
91~111Kpa
|
|
CH4
|
80~116Kpa
|
|
CO(2000ppm)
|
80~120Kpa
|
|
Preheat time
|
NH3/H2/CO/H2S/CH4/NO2/SO2/O3/O2/PH3: ≥5 minutes
|
Detailed Images
The RS-*-N01-C gas leak detector is an environmental gas concentration monitor independently developed by our company. It is used to detect the gas concentration parameters in the air environment. When the concentration exceeds the preset alarm value, it will send out an audible and visual alarm signal to remind the user in time Take safety measures to prevent explosions and poisoning accidents, so as to ensure the safety of life and property.
Gas name
|
Optional range
|
Resolution
|
Accuracy
|
Zero drift
|
Response
|
O2
|
0-30%VOL
|
0.1 %VOL
|
±2%FS
|
±0.3%VOL
|
≤10S
|
H2S
|
0-100 ppm
|
1 ppm
|
±2ppm or ±10%
|
±5ppm
|
≤35S
|
CO |
0-1000 ppm
|
1 ppm
|
±5ppm or ±10%
|
±3ppm
|
≤30S
|
0-2000ppm
|
1 ppm
|
±5ppm or ±10%
|
≤±10ppm
|
≤30S
|
|
CH4
|
0-100 %LEL
|
1 %LEL
|
±5%FS
|
≤±0.06%
|
≤15S
|
NO2 |
0-20 ppm
|
0.1 ppm
|
±5%FS
|
≤±0.5ppm
|
≤30S
|
0-2000 ppm
|
1 ppm
|
±5%FS
|
≤±20ppm
|
≤60S
|
|
SO2 |
0-20 ppm
|
0.1 ppm
|
±5%FS or±10%
|
≤±0.5ppm
|
≤45S
|
0-2000 ppm
|
1 ppm
|
±5%FS or±10%
|
≤±4ppm
|
≤70S
|
|
H2 |
0-1000 ppm
|
1 ppm
|
±5%FS
|
≤±10ppm
|
≤70S
|
0-40000 ppm
|
1 ppm
|
±5%FS
|
≤±20ppm
|
≤60S
|
|
NH3 |
0-50 ppm
|
0.1 ppm
|
±8%
|
≤±2ppm
|
≤90S
|
0-100 ppm
|
1 ppm
|
±8%
|
≤±2ppm
|
≤90S
|
|
O3
|
0-100ppm
|
1 ppm
|
±6%FS(@50ppm,25℃,50%RH)
|
≤±0.5ppm
|
≤30S
|
CO2
|
0-2000ppm
|
1 ppm
|
±(50ppm+3%FS) @(25℃,400~-2000ppm)
|
/
|
≤30S
|
0-5000ppm
|
1 ppm
|
±(50ppm+3%FS) @(25℃,400~-5000ppm)
|
/
|
≤30S
|
Output method
Sensor, communication gateway, industrial data platform, cloud computing service,and measurement control technology solution. We have won good reputation for high quality products and sincere service. Renke insists on the policy that”technology first, exquisite design, customer satisfied” we are careful with every detail. Every drawing has to be considered and revised repeatedly. Every products is the thought of designer.